Array of Pogo Pins |
Top of Pogo Pin at Mag. 30 X |
Cross sectioned Pogo Pins at Mag. 5 X |
1. Through the optical microscope the pins from both lots were found to have good gold plating. On the upper left is a photomicrograph of the surface of a "bad" pin.
2. In both cases testing the Pogo pins with a needle showed good contact all through the instrument.
3. Samples were cross sectioned and both lots showed good plating on the interior of the Pogo pins. Center photomicrograph.
The client was advised that there was no bad lot. It was suggested that the Pogo pins be wiped with isopropyl alcohol and retested. This test was successful; therefore one must conclude that a contaminant film settled on the contact surfaces during the wave solder operation. The alcohol wipe was added to the procedure.