Botle Manufacturing Defect
![](https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEhMvH4vFeM7yPPc3WpniKp1ks7iy5Vc0RmST8JwUldKvCHXZy6cJVtYcX55ukig9IyPnFLldP35xmeMM6cJJJMPgdF4bzpLbDwLwbWckPhd3vaMzZLUgaOeNbkcIlYoqlrNeo4z/s200/IMG_3392+FA+AS.jpg)
![](https://blogger.googleusercontent.com/img/b/R29vZ2xl/AVvXsEiX1_egkcDbhSp9wDThzD_su9MsQHhyhyphenhyphenksbZd-Y5t6_PoFEK1b2jKxfUaJB91JgRmDDCA_a-nSDgGAwKa6O-B3GRIJnW10yGeYn80c15WEUmebx-2q-kjd7Zcx8O_Qc3IJIiTA/s200/IMG_3405+AS.jpg)
Glass failure analysis expert performs a root cause failure analysis on a bottle failure. In this case a manufacturing defect was causing numerous failures on a manufacturing line. The tops of these small bottles were coming off. The upper left photomicrograph is with the two halves of the bottle re-assembled. The upper right photomicrograph is of one of the glass fracture surfaces. The failures were occuring just below the transfer ring at a glass molding defect. The molding defect is a fold in the glass that acts as a stress concentrator. The lower left photograph is of an unused bottle with the defect. This is an unacceptable manufacturing defect and the parts werre returned as non-conforming.
Labels: failure analysis expert, Glass failure anlysis expert, glass fracture, manufacturing defect, molding defect, root cause failure analysis